F2102 It Was Impossible To Address I2C Memory - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
Rexroth IndraDrive

F2102 It was impossible to address I2C memory

Cause
Failure occurs sporadically (firmware error)
Encoder cable defective or bad shielding
Encoder memory or encoder electronics is defective
Hardware defect on control section
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
When addressing a memory via the I
Remedy
Clear error and contact our service department in order
to get a firmware update
Clear error. Replace defective encoder cable or improve
shielding
Clear error. Replace encoder or motor
Replace control section or entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
See also Functional Description "Measuring Systems"