6-30
Status Diagnostic Messages

A0154 Position mode with encoder 1 drive controlled

A0155 Position mode with encoder 2 drive controlled

LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The drive is in position control. The position control loop is closed by
means of a position encoder in the drive. The drive presets the position
command value characteristic internally and follows the command value
with a lag distance.
"Encoder 1" means that the encoder assigned by means of P-0-0077,
Assignment motor encoder->optional slot is used as a control
encoder.
See also Functional Descriptions "Drive-Internal Interpolation" and "Drive-
Controlled Positioning"
A0154 - Attributes
Display:
AF
Mess. no.:
A0154 (hex)
Supported by Firmware Variant:
The drive is in position control. The position control loop is closed by
means of a position encoder in the drive. The drive presets the position
command value characteristic internally and follows the command value
with a lag distance.
"Encoder 2" means that the encoder assigned by means of P-0-0078,
Assignment optional encoder->optional slot is used as a control
encoder.
See also Functional Descriptions "Drive-Internal Interpolation" and "Drive-
Controlled Positioning"
A0155 - Attributes
Display: