F8023 Error mechanical link of encoder or motor connection

Cause
Mechanical connection between rotor of motor and
motor encoder is loose or broken
Phase break in motor feed wire

F8027 Starting lockout while drive enabled

Cause
Starting lockout was activated with drive enable
having been set
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The controller is monitoring the motor, among other things, by means of a
model calculation. The input values required for the model calculation are
checked for plausibility. If the check is negative, this error message is
generated.
Remedy
Check connection and fix or repair it
- Check motor feed wire for continuity. Take possible
"loose contacts" into account.
- Check connection of motor feed wire at controller.
- Check connection of motor feed wire at motor.
- Line break in motor. Replace motor.
- Line break in controller. Replace controller.
F8023 - Attributes
Display:
F8023
Mess. no.:
F8023 (hex)
Supported by Firmware Variant:
In the drive a monitoring function ensures that the starting lockout cannot
be set with control being active.
Note:
When the error occurs, the drive immediately becomes torque-
free!
Remedy
Check control and connection of starting lockout input
F8027 - Attributes
Display:
F8027
Mess. no.:
F8027 (hex)