Error Messages When Booting The Devices; Plc; Stop Plc; Run Plc - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
4-2
Diagnostic Messages when Booting the Devices
4.3

Error Messages when Booting the Devices

PLC ?

Stop PLC

Run PLC

No IDN on MMC !

Cause
Content of MMC is incorrect. Parameter (*.pbf) or
retain file (*.rbf) is missing
MMC was not formatted correctly
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Brief Description: PLC start dialog
Before "Boot 2.9" was displayed on the control panel the buttons "ESC"
and "ENTER" had been simultaneously pressed and kept pressed on the
control panel.
As the functional package "Motion Logic" (drive PLC and technology
functions) has been enabled, the display reads "PLC ?". The automatic
start of a PLC boot project was prevented.
By pressing the arrow buttons (arrow down or arrow up) the display
changes between "Run PLC" and "Stop PLC".
Brief Description: Do not start PLC after booting
Pressing the "ENTER" button on the control panel prevents the start of a
PLC boot project.
Brief Description: Start PLC after booting
When the "ENTER" button is pressed on the control panel, the drive PLC
and a possibly available boot project are started after the booting process.
Brief Description: MMC was not formatted correctly
Remedy
Switch drive off and plug in MMC with correct content
Switch drive off and plug in appropriate MMC
– or –
Switch drive off and format MMC again on PC and plug
it in again
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P

Hide quick links:

Table of Contents
loading

Table of Contents