Rexroth IndraDrive
F2820 Braking resistor overload
Cause
Allowed deceleration of connected drives too high
Energy absorption capacity of braking resistor is
exhausted
Regenerated energy in machining cycle is too high
Continuous regenerative power and/or rotary drive
energy is too high
Device is defective
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Supported by Firmware Variant:
Supported by Supply Unit:
Power was switched off due to overload of the braking resistor.
Note:
After having eliminated the cause of the error check the
braking resistor for operatability!
Remedy
Reduce deceleration of connected drives
Switch power supply off with a delay in the case of drive
OFF or E-STOP (for regenerative supplies) or reduce
velocity
Increase cycle time or reduce maximum velocity
Reduce maximum velocity or check dimensioning of
braking resistor and, if necessary, increase
dimensioning
Replace device
See also Functional Description "Power Supply"
F2820 - Attributes
Display:
F2820
Mess. no.:
F2820 (hex)
Error Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
7-123