F3133 Error when checking interrupting circuits

Cause
An error was detected during check of interrupting
circuit
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
In order to lock the output stage in a safety related way when the safety
technology has detected an error, the correct functioning of the
interrupting circuit is cyclically checked. This is done on the one hand
during the actions "release output stage" and "lock output stage", on the
other hand statically while the output stage is being released or locked.
The corresponding hardware realization ensures that this is possible
without repercussion on the PWM control signals.
Note:
When the safety technology has been activated, the error
F3133 only occurs in normal operation. When a safety function
is selected, the cause of the error causes the error F8133
Error when checking interrupting circuit to be triggered.
The drive is decelerated according to the setting in P-0-0119, Best
possible deceleration.
The drive automatically switches to "safety related standstill" and the
output stage is switched off via one channel.
Note:
Safety is not acknowledged; i.e. "safety technology status
output controller" was cleared/reset in P-0-3214, Safety
technology signal status word, channel 1 or the diagnosis
input/output I/O10n (channel 2) was set depending on the
parameterization in P-0-3210, Safety technology control
word.
Remedy
Start command S-0-0099, C0500 Reset class 1
diagnostics in order to clear error an then set drive
enable again.
If error occurs repeatedly, replace control section or
entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.