C1217 Setting Only Possible In 'Ab - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
Rexroth IndraDrive

C1217 Setting only possible in 'Ab'

Cause
The drive was not ready at the start of the command,
the display did not read "Ab"
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the command for commutation offset
determination (C1200) an error was detected.
Remedy
1. Switch drive to communication phase 4, if there isn't
any error present the display reads "bb"
("betriebsbereit" = ready for operation)
2. Switch power on, drive goes to operating mode, the
display reads "Ab" ("Antrieb bereit" = drive ready)
3. Now start command C1200
C1217 - Attributes
Display:
C1217
Mess. no.:
C1217 (hex)
Command Diagnostic Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
9-87