F3145 Error when unlocking the safety door

Cause
Error in mechanical system of safety door
Error in wiring of safety door, e.g. short circuit
between I/O10n and 24 V or O10n and 0 V; driver at
output of O10n defective
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The drive is decelerated according to the setting in P-0-0119, Best
possible deceleration
- or -
the axis already is in "safety related standstill".
The output stage is switched off via two channels.
Remedy
Check mechanical system of safety door
Check wiring of safety door
Then start command S-0-0099, C0500 Reset class 1 diagnostics in
order to clear error and then set drive enable again.