C0102 Limit Error In Parameter (-> S-0-0021); C0103 Parameter Conversion Error (->S-0-0021) - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
9-18
Command Diagnostic Messages
C0102 Limit error in parameter (-> S-0-0021)
Cause
Parameter values required in communication
phase 3 are outside their allowed range of values
(minimum or maximum value)
C0103 Parameter conversion error (->S-0-0021)
Cause
Parameter values required in communication
phase 3 cannot be processed
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
While the command S-0-0127, C0100 Communication phase 3
transition check is executed, the limit values (minimum/maximum value)
are checked for some parameters. An error was detected during the
execution of the command.
Remedy
Write allowed values to parameters (cf.
minimum/maximum value) (these parameters can be
taken from list S-0-0021, IDN list of invalid operating
data for communication phase 2)
For removing command errors see "Command Errors"
C0102 - Attributes
Display:
C0102
Mess. no.:
C0102 (hex)
Supported by Firmware Variant:
While the command S-0-0127, C0100 Communication phase 3
transition check is executed, the internal parameter formats are
checked in order to ensure the internal processing. An error was detected
during the execution of the command.
Remedy
Write allowed values to parameters (these parameters
can be taken from list S-0-0021, IDN list of invalid
operating data for communication phase 2)
For removing command errors see "Command Errors"
C0103 - Attributes
Display:
C0103
Mess. no.:
C0103 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
DOK-INDRV*-GEN-**VRS**-WA01-EN-P

Hide quick links:

Table of Contents
loading

Table of Contents