Error Messages

F3152 Incorrect backup of safety technology data

Cause
When switching to parameter mode – and therefore
when deactivating safety technology functions - error
occurred in channel 2 (e.g. output stage cannot be
switched on/off via channel 2)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
Remedy
Start command S-0-0099, C0500 Reset class 1
diagnostics in order to clear error an then set drive
enable again.
If necessary, reset module by switching control voltage
on and off