C2803 Measured Values At Zero Point And Max. Value Identical; C2804 Automatic Adjust Failed - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
Rexroth IndraDrive

C2803 Measured values at zero point and max. value identical

Cause
During zero point and gain adjust, the same
voltage value was provided at analog input

C2804 Automatic adjust failed

DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the command P-0-0220, C2800 Analog input
adjust command an error was detected. The execution of the command
was aborted.
Remedy
Voltage provided at input has to be modified between
two steps of adjust (voltage value for zero adjust: 0 V,
voltage value for gain adjust: maximum input voltage)
See also Functional Description "Analog Inputs"
C2803 - Attributes
Display:
C2803
Mess. no.:
C2803 (hex)
Supported by Firmware Variant:
The command P-0-0220, C2800 Analog input adjust command was
aborted due to an unspecified error. Please contact our service
department.