E2040 Device overtemperature 2 prewarning

Cause
Ambient temperature too high. Specified
performance data are valid up to an ambient
temperature of 40 C
Heat sink of device is dirty
Convection is prevented by other components or
mounting position of control cabinet
Blower of device is defective
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
A switch-off value for the second temperature sensor is stored in
element 3 of parameter P-0-4059, Electric type data of power section.
If the parameter P-0-0816, Amplifier temperature 2 exceeds a value that
is 5 °C below this switch-off threshold, the warning E2040 is generated.
Before the switch-off threshold has been reached and the device is
switched off (F2040) it is possible to shut down the axis via the control
unit in accordance with the process (e.g. terminate processing, leave
collision area etc.) or to reduce the load of the drive controller.
Remedy
Reduce ambient temperature, e.g. by cooling the control
cabinet
Clean heat sink
Mount device vertically and provide sufficient space for
ventilating heat sink
Replace device