F8120 Invalid Control Section/Firmware Combination; F8122 Control Section Defective - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
Rexroth IndraDrive

F8120 Invalid control section/firmware combination

Cause
Inappropriate firmware
Inappropriate control section

F8122 Control section defective

Cause
Hardware of control section is defective
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The control section is incompatible with the firmware used.
Remedy
Use firmware that matches control section
Use control section that matches firmware
F8120 - Attributes
Display:
F8120
Mess. no.:
F8120 (hex)
Supported by Firmware Variant:
During the initialization of the control section an error occurred.
Remedy
Replace control section or entire drive controller; use
hardware configuration of same type
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
F8122 - Attributes
Display:
F8122
Mess. no.:
F8122 (hex)
Error Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
7-21