C0751 Parameter Default Value Incorrect (-> S-0-0021); C0752 Locked With Password - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
Rexroth IndraDrive
C0751 Parameter default value incorrect (-> S-0-0021)

C0752 Locked with password

DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The S-0-0262, C07_x Load defaults procedure command with the
"load basic parameters" option was started. An error occurred when
writing a default value. The faulty parameter is displayed in S-0-0021.
Note:
The faulty parameter is recorded in the S-0-0021, IDN list of
invalid
operating
parameter.
C0751 - Attributes
Display:
C0751
Mess. no.:
C0751 (hex)
Supported by Firmware Variant:
During the execution of the C07_1 Load defaults procedure com. (load
basic parameters) command an error occurred.
Cause:
The drive parameters were write-protected by means of the S-0-0267,
Password parameter. The C0752 diagnostic message signals that the
C07_1 Load defaults procedure com. (load basic parameters)
command was started without first deactivating the customer password.
Remedy:
Deactivate the write protection by entering the password. Start the
command again.
See also Functional Description "Using a Password"
C0752 - Attributes
Display:
C0752
Mess. no.:
C0752 (hex)
Command Diagnostic Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
data
for
communication
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
9-79
phase 2

Hide quick links:

Table of Contents
loading

Table of Contents