C2602 Error when accessing the MMC

Cause
MMC has not (or not completely) been plugged in
the MMC slot provided for this purpose
MMC was not or not correctly formatted
MMC is defective
MMC slot in control section is defective
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the command P-0-4092, C2600 Copy IDN from
internal memory to optional memory a check is run in order to find out
whether a functioning MMC (MultiMediaCard) is available.
Note:
The MMC can only be used as an optional memory for control
sections with MMC slot.
Remedy
Put MMC into controller. Then restart command
P-0-4092, C2600 Copy IDN from internal memory to
optional memory
Format MMC or contact our service department. Then
restart command P-0-4092, C2600 Copy IDN from
internal memory to optional memory
Check MMC and restart command P-0-4092, C2600
Copy IDN from internal memory to optional memory.
If diagnostic message appears repeatedly: replace MMC
Check MMC slot and, if necessary, replace control
section or complete drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
Note:
If the MMC must be replaced, the values stored on it are lost.
See also Functional Description "MultiMediaCard (MMC)"
C2602 - Attributes
Display:
C2602
Mess. no.:
C2602 (hex)
Command Diagnostic Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS