Xx:f9002; Xx:f2100; Xx:f Cks; Xx:f Acc - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
10-4
Handling, Diagnostic and Service Functions

XX:F9002

XX:F2100

XX:F CKS

Cause
Checksums of programmed modules are calculated
after firmware update. Calculated and entered
checksums were detected to be different

XX:F ACC

Cause
Several possibilities of firmware update (serial and
MMC) were used simultaneously. An access
conflict has occurred

XX:F2101

LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Brief Description: Error: operating system error
See F9002 Error internal RTOS function call
Brief Description: Error: internal memory defective
See F2100 Incorrect access to command value memory
Brief Description: Error: checksum error
Remedy
Carry out firmware update again; should error occur
again, please contact our service department
Note:
"FL:F CKS" means firmware loader and "LD:F CKS" means
loader in control section.
Brief Description: Error: access error
Remedy
Restart firmware update using only one possibility (serial
or MMC)
Note:
"FL:F ACC" means firmware loader and "LD:F ACC" means
loader in control section.
Brief Description: Error: MMC defective
See F2101 It was impossible to address MMC
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P