F2104 Commutation Offset Invalid - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents
Rexroth IndraDrive

F2104 Commutation offset invalid

Cause
Failure occurs sporadically (firmware error)
Encoder memory or encoder electronics is defective
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The commutation offset value stored in the motor encoder memory was
detected to be invalid.
Note:
The motor mustn't be operated without valid commutation
offset!
Remedy
Clear error. Then execute command P-0-0524, C1200
Commutation offset setting command; if error occurs
again contact our service department in order to get a
firmware update
Clear error. Replace encoder or motor. Then execute
command P-0-0524, C1200 Commutation offset
setting command.
See also Functional Description "Commutation Setting"
F2104 - Attributes