F2044 External power supply X15 error

Cause
Temporary failures (voltage peaks) or voltage drops
At least one of the inputs was connected with
reversed polarity
At least one of the outputs has short circuit or is
overloaded
Voltage drops because motor brake applied
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
The external 24 V power supply for the digital I/Os at the optional module
(HCC01) is monitored by the drive.
If the 24 V power supply is outside of the range of 19 V to 30 V, the error
F2044 is generated.
Remedy
Use controlled power supply unit
Check wiring incl. cable and correct it, if necessary
Check wiring incl. cable and remove short circuit, if
necessary
Supply motor brake and interface with different power
supply units, especially with long motor cables