F2077 Current measurement trim wrong

Cause
Hardware of control section or power section
defective
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
The current measurement in the drive controller is adjusted in operation.
The adjust values are checked for compliance with the allowed tolerance.
If the values are higher the error message F2077 is generated.
Remedy
Replace power section or control section resp. entire
drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section or the power section.
The replacement of the entire drive controller is described in
the Project Planning Manual for the power section.