F8010 Autom. commutation: max. motion range when moving back

Cause
Positive feedback of motor; commutation offset
determination generated incorrect value for
P-0-0521, Effective commutation offset
Positive feedback of motor after axis was mounted,
in spite of successful initial commissioning before
axis was dismounted
During commutation setting process, axis got into
resonance
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Supported by Firmware Variant:
When moving back to the initial position at which it was before
commutation setting (only in the case of sine-wave method with motion),
the axis left the allowed actual position value range.
Remedy
Check motor encoder signals. To do this move motor
knowing manufacturer-side setting for sense of rotation
or velocity polarity and check actual position values with
regard to polarity and plausibility.
If necessary, invert polarity of motor encoder or invert
two motor phases. Carry out commutation setting again
Check whether direction of motion (sense of rotation) of
motor complies with that of motor encoder. If not, invert
direction of motion of motor (invert phases) or of motor
encoder
Set "search direction for sine-wave method" to "increase
of frequency with priority" in P-0-0522, Control word for
commutation setting
- or -
Reduce value in P-0-0507, Test frequency for angle
acquisition in order modify excitation frequency for
sine-wave method compared to resonance frequency of
axis