Fieldbus Communication

9 Fieldbus Communication

9.1 Brief Introduction

FcP 5020 frequency converter provides standard communication interface to re-
alize the communication between the master and slave via Modbus, Profibus,
Profinet, CANopen, Ethernet and other protocols. With the help of a PC, a PLC
or an external computer a ''single master / multiple slaves'' network control can
be realized (setting of pressure command, flow command, modification of pa-
rameters, monitoring of frequency converter running status and error messages)
to address the specific requirements of applications.
Cycle time for command and status value exchanging is 2ms.
Bus communication and internal ASF data communication are not
synchronized.

9.2 Frequency Converter Parameter Address

Frequency converter parameter registers correspond to the function codes one-
to-one. Reading and writing of related function codes can be achieved through
reading and writing of the contents in frequency converter parameter registers
via communication. The characteristics and scope of reading and writing func-
tion codes are in compliance with the frequency converter function code de-
scription. The address of a frequency converter parameter register is composed
of a higher byte representing the function code group and a lower byte repre-
senting the index in the group. The groups are mapped as follows:
Address high byte
Group
Tab. 9-1: Frequency converter parameter registers
Code
Name
F0.20 ASF command 1
F0.21 ASF command 2
F0.22 ASF command 3
F0.23 ASF command 4
Tab. 9-2: Communication protocol
Bit
0
Reserved
1
Reserved
76/83
0x50
0x51
F0
F1
Description
ASF control word
Pressure command
Flow command
Reserved
Description
0x52
0x53
F2
F3
Setting range
0...65,535
0.0...1,000.0 (0.0...1,000.0 bar)
0...5,000 (0...5,000 rpm)
-
Setting range
-
-
DOK-RCON03-FCP5020****-QU04-EN-P
FcP 5020
0x54
F4