8.5 Group F4: System Protection and Pump Function Parameter

Code
Name
Protection function configuration
F4.00
word
F4.03 Pump function configuration word
Pressure sensor failure detection
F4.06
threshold 1 (negative direction)
Pressure sensor failure detection
F4.07
time 1 (negative direction)
Pressure sensor failure detection
F4.08
threshold 2 (positive direction)
Pressure sensor failure detection
F4.09
time 2 (positive direction)
Pressure sensor detection thresh-
F4.10
old (standby)
Pressure sensor detection period
F4.11
(standby)
Maximum system pressure (warn-
F4.15
ing)
F4.16 Maximum pump pressure (error) [F4.15]...4,000.0 bar
Maximum system pressure warn-
F4.17
ing time delay
Maximum pump pressure error
F4.18
time delay
F4.20 p/Q command soft start delay
DOK-RCON03-FCP5020****-QU04-EN-P
Setting range
0...15
Bit0: Pressure sensor failure
(PSF)
Bit1: Actual pressure moni-
toring
Bit2: p/Q max. command lim-
it
Bit 3: Oil changing detection
0...63
Bit0: Pump power limit
Bit1: Pump thermal protec-
tion
Bit2: Switch master to slave
Bit3: Two points / double
pump
Bit4: Pressure drop / over-
shoot compensation
Bit5: Activating myCro
-5,000...0 rpm
0.1...100.0 s
0...5,000 rpm
0.1...100.0 s
1.0...1,000.0 bar
0.1...100.0 s
0.0...[F4.16] bar
0.0...6000.0 s
0.0...6000.0 s
0.0...1,000.0 s
Bosch Rexroth AG
FcP 5020 Parameter List
Default
Min.
0
-
0
-
-1
1
10.0
0.1
200
1
10.0
0.1
5.0
0.1
1.0
0.1
500.0
0.1
1,000.0
0.1
0.0
0.1
0.0
0.1
0.0
0.1
Attri.
Run
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Run
Run
Stop
71/83