8.2 Group F1: Quick Start Parameter

Code
Name
F1.00 ASF parameter initialization
F1.02 Control mode
F1.03 Pressure command source
F1.04 Pressure command selection
Pressure command digital set-
F1.05
ting 0
Pressure command digital set-
F1.06
ting 1
Pressure command digital set-
F1.07
ting 2
Pressure command digital set-
F1.08
ting 3
F1.11 Flow command source
F1.12 Flow command digital setting
DOK-RCON03-FCP5020****-QU04-EN-P
Setting range
0: Inactive
1: Restore to FcP default set-
tings
2: Deactivate ASF
0: p/Q control
1: Flow control
2: Pressure control
0: Depend on the value of
F1.04
1: Select by digital input (F1.04
shows status)
2: Analog input
3: Communication
0: Pressure command digital
setting 0
1: Pressure command digital
setting 1
2: Pressure command digital
setting 2
3: Pressure command digital
setting 3
0.0...1,000.0 bar
0.0...1,000.0 bar
0.0...1,000.0 bar
0.0...1,000.0 bar
0: Depend on the value of
F1.14
1: Analog input (positive / nega-
tive)
2: Communication
3: Select by digital input (F1.14
shows status)
0...5,000 rpm
Bosch Rexroth AG
FcP 5020 Parameter List
Default
Min.
0
-
0
-
0
-
0
-
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
0
-
400
1
Attri.
Stop
Stop
Stop
Run
Run
Run
Run
Run
Stop
Run
63/83
Table of Contents