Pressure And Flow Command Limit - Bosch rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for rexroth Sytronix FcP 5020:
Table of Contents
Bosch Rexroth AG
Block Diagram of Main Functions

7.10.5 Pressure and Flow Command Limit

Code
Name
Protection function configura-
F4.00
tion word
Minimum pressure command
F4.21
limit
Maximum pressure command
F4.22
limit
F4.23 Minimum flow command limit 0...[F4.24] rpm
F4.24 Maximum flow command limit [F4.23]...5,000 rpm
Tab. 7-23: Parameter list of pressure and flow command limit
The minimum pressure and flow command limitation (F4.21 and F4.23) works all
the time, independently to any control bit. That means if the setting pressure or
flow command is lower than [F4.21] or [F4.23], it will be limited to [F4.21] or
[F4.23] without any error / warning message.
The maximum pressure and flow command limitation can be activated via bit2 of
F4.00. This function will check whether the pressure or flow command given by
customer exceeds the limitation set in [F4.22] and [F4.24]. If a given command
exceeds its limitation, the effective command value will be limited to the maxi-
mum limit, and a warning signal will be raised.
50/83
Setting range
0...15
Bit0: Pressure sensor failure (PSF)
Bit1: Actual pressure monitoring
Bit2: p/Q max. command limit
Bit3: Oil changing detection
0.0...[F4.22] bar
[F4.21]...1,000.0 bar
Default
Min.
0
-
5.0
0.1
250.0
0.1
200
1
3,000
1