DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
7.1.9
Analog current input
Spring terminal (connector)
Input current measuring range
Input current minimum value monitoring
Input current maximum value monitoring
Input resistance
Input bandwidth (-3db)
Relative measuring error at 18 mA
Resolution
Overload protection
4)
Wiring
AD
Analog/digital converter
Fig. 7-33:
Analog current input
Electrical data (current inputs [-20/4 ... 20 mA])
Unit
mA
1)
mA
2)
mA
3)
Ω
kHz
%
-
-
-
1)
Measuring range (-20 ... 20 or 4 ... 20) can be set using a pa‐
rameter. With a measuring range 4 ... 20, the minimum value
monitoring (wire break) is automatically active.
2)
Only possible with a measuring range 4 ... 20
3)
Monitoring switched off at approx. ±35 mA
4)
In the case of input currents greater than the maximum value,
an error is signaled and the input is switched at high resistance
5)
Applies to: Optional I/O extension DA (X38)
6)
Applies to: Control sections with extended scope CSx02.1B
(X35), CDB02.1B (X36)
Tab. 7-37:
Electrical data
Bosch Rexroth AG
Technical data of the components
min.
-20 / 4
2
21
280
1.3
-1
13bit (12bit + 4-fold oversampling)
12bit (11bit + 4-fold oversampling)
Present
Only use shielded cables for cable lengths > 30 m.
227/341
max.
20
3
22
+1
5)
6)