Selecting the mains filter

HCS01.1E-W0005, -W0008, -W0018-A-03, -W00028, -W00054
Nominal voltage of mains filter: 3 × 400 V
Clock frequency
Leakage capacitance (motor + ca‐
[kHz]
4; 8
12; 16
HCS01.1E-W0005, -W0008, -W0018-A-03, -W00028, -W00054
Nominal voltage of mains filter: 3 × 400 ... 500 V
Clock frequency
Leakage capacitance (motor + ca‐
[kHz]
4; 8
4; 8
12; 16
12; 16
When using NFE02 or NFD03 mains filters at mains grounded via
outer conductor, install an isolating transformer between mains
and mains filter.
The specified mains filter types are exclusively suited for TN and
TT mains.
The EMC limit values relate to line-based noise emission in the
frequency range of 0.15 ... 30 MHz on the mains connection
lines.
ble)
[nF]
< 100
< 30
1)
Leakage capacitances > 100 nF overload the mains filter (over‐
temperature, saturation phenomenon)
Tab. 4-36:
Mains filter; 3 × 400 V
ble)
[nF]
< 70
70 < ... < 100
< 20
20 < ... < 50
Tab. 4-37:
Mains filter; 3 × 400 ... 500 V
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
Mains filters
NFD03.1
1)
Mains filters
FN3258H (Schaffner)
EMC limit value class to be ach‐
ieved
(IEC / EN 61800-3)
C2
EMC limit value class to be ach‐
ieved
(IEC / EN 61800-3)
C2
C3
C2
C3