Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual page 72

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
70/341
Bosch Rexroth AG
Combining the individual components
Basic device power requirements
Power requirements of the option‐
al connection points
Type code example:
A
Basic device (maximum current [W0028 = 28 A], series [03],
on-board connection point [EC])
B
Control section design (E = Economy; S3 = sercos III)
C
Optional connection points (PB = ProfiBus; L4 = safety technol‐
ogy [STO, SBC])
Fig. 4-13:
Type code HCS01
The tables below contain the individual power values required by the drive
controller. The power requirement of the supplying 24 V power supply unit re‐
sults from the sum of these individual power values.
The power requirements of the basic device result from
Maximum current of drive controller
Control section design
Table 1: Basic device power requirements
Maximum current, series
HCS01.1E-...
W0003-A-02-x-xx-EC
W0006-A-02-x-xx-EC
W0009-A-02-x-xx-EC
W0013-A-02-x-xx-EC
W0018-A-02-x-xx-EC
W0005-A-03-x-xx-EC
W0008-A-03-x-xx-EC
W0018-A-03-x-xx-EC
W0028-A-03-x-xx-EC
W0054-A-03-x-xx-EC
The wild card x-xx in this column represents the control section
1)
design. Example: The basic device HCS01.1E-W0028-A-03-E-
S3-EC has a power requirement of 12.7 W.
Tab. 4-21:
Basic device power requirements
If the drive controller has optional connection points, the power requirements
of the basic device are increased.
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
Control section design
1)
E-S3
(ECONOMY)
(BASIC)
8.1 W
12.7 W
9.4 W
14.3 W
12.7 W
17.3 W
9.4 W
14.3 W
12.7 W
17.3 W
25.7 W
30.3 W
B-ET
A-CC
(ADVANCED)
13.4 W
15 W
18 W
15 W
18 W
31 W

Hide quick links: