70/341
Bosch Rexroth AG
Combining the individual components
Basic device power requirements
Power requirements of the option‐
al connection points
Type code example:
A
Basic device (maximum current [W0028 = 28 A], series [03],
on-board connection point [EC])
B
Control section design (E = Economy; S3 = sercos III)
C
Optional connection points (PB = ProfiBus; L4 = safety technol‐
ogy [STO, SBC])
Fig. 4-13:
Type code HCS01
The tables below contain the individual power values required by the drive
controller. The power requirement of the supplying 24 V power supply unit re‐
sults from the sum of these individual power values.
The power requirements of the basic device result from
●
Maximum current of drive controller
●
Control section design
Table 1: Basic device power requirements
Maximum current, series
HCS01.1E-...
W0003-A-02-x-xx-EC
W0006-A-02-x-xx-EC
W0009-A-02-x-xx-EC
W0013-A-02-x-xx-EC
W0018-A-02-x-xx-EC
W0005-A-03-x-xx-EC
W0008-A-03-x-xx-EC
W0018-A-03-x-xx-EC
W0028-A-03-x-xx-EC
W0054-A-03-x-xx-EC
The wild card x-xx in this column represents the control section
1)
design. Example: The basic device HCS01.1E-W0028-A-03-E-
S3-EC has a power requirement of 12.7 W.
Tab. 4-21:
Basic device power requirements
If the drive controller has optional connection points, the power requirements
of the basic device are increased.
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
Control section design
1)
E-S3
(ECONOMY)
(BASIC)
8.1 W
12.7 W
9.4 W
14.3 W
12.7 W
17.3 W
9.4 W
14.3 W
12.7 W
17.3 W
25.7 W
30.3 W
B-ET
A-CC
(ADVANCED)
13.4 W
15 W
18 W
15 W
18 W
31 W