Tions - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
198/341
Bosch Rexroth AG
Technical data of the components
Allowed encoder cable length for
resolver encoder systems
I [mA]
Encoder current consumption
l [m]
Cable length
Line cross sections
0.5 mm
; 1.0 mm
2
2
Fig. 7-15:
Maximum allowed encoder cable lengths for 12 V encoder systems
depending on line cross section at supply voltage of 10 V
Nominal current consumption of the MSK motor encoders: 60 mA
75 m at most (The cross section of the supply voltage lines has to be at least
0.5 mm
2
.)
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01