Cables; Motor Power Cables; Selection; Allowed Cable Lengths - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
4.3.5

Cables

Motor power cables

The continuous current of the drive controller should be greater
than the continuous current of the motor.
The continuous power of the drive controller must be greater than
the required average power!
Selecting the Connection Technique
For the available power cables and encoder cables, see documentation
"Rexroth Connection Cables IndraDrive and IndraDyn".
Notes on Commissioning
For further information, notes on commissioning and supporting
documents (e.g., forms for entering the required data) see firm‐
ware documentation.

Selection

How to select a suitable motor power cable:
See documentation "Rexroth Connection Cables IndraDrive and IndraDyn"
(R911322949).

Allowed cable lengths

Allowed cable lengths at ambient temperature T
EN 60 204:
HCS01.1E-...-A-02
W0003
W0006
W0009
W0013
W0018
HCS01.1E-...-A-03
W0005
W0008
W0018
W0028
W0054
Tab. 4-11:
Allowed motor cable lengths
Bosch Rexroth AG
Combining the individual components
≤ 40 °C according to
a_work
PWM frequency [kHz]
4
8
40 m
20 m
75 m
38 m
53/341
12
16
15 m
5 m
25 m
-

Hide quick links:

Table of Contents
loading

Table of Contents