X9, Integrated/External Braking Resistor - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01

X9, integrated/external braking resistor

Function
Connection (HCS01.1E-W0003...
W0028)
Connection (HCS01.1E-W0054)
Notes on installation
WARNING
Exclusively operate the device
with plugged on connectors (even if there haven't been any lines con‐
nected to the connectors) and
with connected equipment grounding conductor!
X9 is used to connect the integrated or external braking resistor HLR. By
means of an internal switch, the braking resistor is connected to the DC bus.
Parameterize the external braking resistor by means of the firm‐
ware to protect the drive controller and the braking resistor
against overload:
P-0-0860, Converter configuration
P-0-0858, Data of external braking resistor
Fig. 6-7:
Connecting the braking resistor (HCS01.1E-W0003...W0028)
Fig. 6-8:
Connecting the braking resistor (HCS01.1E-W0054)
Maximum allowed line length to external braking resistor: 5 m
Twist unshielded lines.
Bosch Rexroth AG
Mounting and installation
Lethal electric shock by live parts with more
than 50 V!
141/341