Inverter - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
Description
Braking resistor continuous power
Braking resistor peak power
Nominal braking resistor
Braking resistor switch-on thresh‐
old - independent of mains volt‐
age
1)
Braking resistor switch-on thresh‐
old - depending on mains volt‐
age
2)
Maximum allowed on-time duty
Minimum allowed cycle time
Regenerative power to be absor‐
bed
Balancing factor for P
(for paral‐
BD
lel operation at common DC bus)
Cooling of integrated braking re‐
sistor
7.3.5

Inverter

Description
Allowed switching frequencies
Output voltage, fundamental wave
for V/Hz (U/f) control
Output voltage, fundamental wave
for closed-loop operation
Rise of voltage at output with
U
and 15 m motor cable
LN_nenn
length phase-phase (10-90%)
Rise of voltage at output with
U
and 15 m motor cable
LN_nenn
length phase-ground (10-90%)
Integrated braking resistor data
Symbol
Unit
P
kW
BD
P
kW
BS
R
ohm
DC_Bleeder
U
V
R_DC_On_f
U
R_DC_On_v
t
s
on_max
T
s
cycl
W
kWs
R_max
f
1) 2)
Factory setting
Tab. 7-47:
HCS - Integrated braking resistor data
Power section data - inverter
HCS01.1E
Symbol
Unit
f
kHz
1)
s
V
V
out_eff
V
V
out_eff
dv/dt
kV/µs
2)
dv/dt
kV/µs
3)
Technical data of the components
HCS01.1E
HCS01.1E
HCS01.1E
-W0005-
-W0008-
-W0018-
_-03
_-03
0.02
0.03
4.00
180
130% of parameter P-0-0815, 820V at most
0.20
40.00
26.70
0.80
Forced ventilation
HCS01.1E
HCS01.1E
-W0003-
-W0006-
-W0009-
_-02
_-02
_-02
4, 8, 12, 16
~UDC x 0.71
~UDC x 0.71
5.00
5.00
Bosch Rexroth AG
243/341
HCS01.1E
HCS01.1E
-W0028-
-W0054-
_-03
_-03
_-03
0.05
0.15
0.50
7.20
10.60
25.80
100
68
28
820
0.32
0.28
0.50
45.40
20.00
26.00
2.25
3.00
13.00
0.80
Last modification: 2012-05-16
HCS01.1E
HCS01.1E
-W0013-
-W0018-
_-02
_-02
Last modification: 2015-06-12