Tions - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
18/341
Bosch Rexroth AG
System presentation
Short type designation 1 2 3 4 5 6 7 8 9
Example:
H C S 0 1 . 1 E - W 0 0 1 3 - A - 0 2 - E - S 3 - E C - N N - N N - N N - F W
Interface 1:
EC = Multi-encoder interface
Interface 2
CN = CANopen
DA = Digital/analog I/O extension
EC = Multi-encoder interface
EP = Engineering port
EM = Encoder emulation
ET = Multi-Ethernet
NN = Not equipped
PB = PROFIBUS
Interface 3
L3 = STO (Safe Torque Off)
L4 = STO (Safe Torque Off) and SBC
NN = Not equipped
S4 = Safe Motion
S5 = Safe Motion
SB = Safe Motion Bus
Other design:
NN = None
Firmware:
FW = With control panel, firmware has to be ordered separately
NW = Without control panel, without firmware
Mains connection voltage [V]
3 × AC 110 ... 230
3 × AC 200 ... 500
1
0 1 2 3 4 5 6 7 8 9
③ ④
2)
:
:
2) 3)
1)
See table "Possible combinations of maximum current and
mains connection voltage"
2)
See table "Possible combinations of options"
3)
The L3, S4, S5 and SB interfaces guarantee both the function
and the certification
Tab. 1-6:
Type code HCS01
Possible combinations of maximum current and mains connection voltage:
3
5
6
Tab. 1-7:
Possible combinations of maximum current and mains connection
voltage
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
2
0 1 2 3 4 5 6 7 8 9
Maximum current [A]
8
9
13
3
4
0 1 2 3 4 5 6 7 8 9
0
18
28
54

Hide quick links:

Table of Contents
loading

Table of Contents