DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
DC bus connecting bar

DC Bus Capacitor Unit

Function
Mains Choke
Connection
Fig. 4-36:
DC bus connection via connecting bar
Via a "spur line", the DC buses of the individual devices are connected to the
DC bus connecting bar.
The power reserve of the supplying devices limits the number of devices at
the common DC bus.
DC bus capacitor units are optional additional components and increase
the DC bus continuous power
the available DC bus energy
Always operate the DC bus capacitor units together with the mains choke as‐
signed to the drive controller (see
233).
Special case "HCS01.1E-W0018-_-03" (in the technical data, no mains choke
has been assigned to this drive controller):
Use the mains choke "HNL01.1E-1000-N0012-A-500-NNNN".
The maximum allowed capacitance of a DC bus capacitor unit depends on
the device which assumes the DC bus supply.
Even if several devices supply the DC bus, the specific external
DC bus capacitance of the biggest supplying device may only be
connected once for the entire DC bus group!
For the maximum allowed external DC bus capacitance at
U
, see the technical data
LN_nenn
240).
Maximum Allowed External DC Bus Capacitance [mF] vs. Mains Voltage
HCS01.1E-
W0018-A-03
W0028-A-03
W0054-A-03
Tab. 4-43:
Maximum Allowed External DC Bus Capacitance (in mF)
Bosch Rexroth AG
Combining the individual components
chapter 7.3.2 "Mains voltage" on page
(chapter 7.3.3 "DC bus" on page
Mains voltage
400 V
440 V
480 V
3
2
1
4
3
1
13
9
6
111/341
500 V
-
-
5