X13, 24V Supply (Control Voltage) - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01

X13, 24V Supply (Control Voltage)

Function, Pin Assignment
View
Spring terminal (connector)
Connection cable
Stranded wire
Stripped length
Power consumption
Voltage load capacity
Current carrying capacity "looping through" from
0V to 0V, 24V to 24V
Polarity reversal protection
Insulation monitoring
Notes on Installation
The external 24V supply is applied via connection point X13 for
the control section and power section of the drive controller
brake control via X6
the digital inputs and the digital output to X31 / X32
Connec‐
tion
1
2
3
4
Unit
mm
2
AWG
mm
W
V
A
Within the allowed voltage range by internal protective diode
Tab. 6-10:
Function, Pin Assignment, Properties
Requirements on the connection to the 24V supply:
Minimum cross section: 1 mm
Maximum allowed inductance: 100 µH (2 twisted single strands, 75 m
long)
Parallel line routing where possible
Depending on the power consumption of the devices and the current carrying
capacity of the connector X13, check via how many devices one line for 24V
supply can be looped through. You might possibly have to connect another
device directly to the 24V supply and then loop through the control voltage
from this device to other devices.
Bosch Rexroth AG
Mounting and installation
Signal name
0V
Reference potential for pow‐
0V
+24V
+24V
Min.
1,0
16
10
P
(see
data for control
N3
U
(see
data for control
N3
10
Possible
2
143/341
Function
er supply
Power supply
Max.
2,5
12
voltage)
voltage)

Hide quick links:

Table of Contents
loading