Mounting and installation

X5, Motor Connection

Notes on Installation
Important Notes
WARNING
Exclusively operate the device
with plugged on connectors (even if there haven't been any lines con‐
nected to the connectors) and
with connected equipment grounding conductor!
NOTICE
Provide strain relief for the terminal connectors of the device in the control
cabinet.
The equipment grounding conductor is connected directly to the device and
not via the connection point X5.
The indicated connection cross sections are the cross sections which can be
connected. Dimension the required cross section of the connection lines ac‐
cording to the occurring current load.
For optimum shield contact of the motor power cable, use
the supplied accessory HAS09.
For the connection between drive controller and motor, use
our ready-made motor power cables, where possible.
When using NFD03.1 mains filters, the maximum allowed
conductor cross section is limited to 4 mm
DOK-INDRV*-HCS01******-PR05-EN-P