Technical data of the components
7.1.8

Analog Voltage Input

AD
Analog/digital converter
Fig. 7-32:
Analog Voltage Input
Data
Allowed input voltage
Working range input voltage U
Input resistance R
u
Input bandwidth (-3 dB)
Common-mode range
Common-mode rejection
Relative measuring error at 90%
U
on_work
Resolution
Cables
1)
Applies to: Cxx02 control sections (X32), optional I/O extension
DA (X38), HCS01 drive controllers (X32)
2)
Applies to: Control sections with extended scope CSx02.1B
(X35), CDB02.1B (X36)
Tab. 7-36:
Analog Voltage Input
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
Unit
Min.
V
-30
V
-10
on_work
150
kHz
V
-30
dB
50
%
-1
Bit
For cable lengths > 30 m, only use
shielded cables.
Typ.
Max.
+30
+10
300
1,3
+30
+1
14
1)
13
2)