X3, Mains Connection Hcs01.1E-W0054-X-03 - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
View
Terminal block
Connection cable
Stranded wire
Stripped length
Tightening torque
Occurring current load and minimum required
connection cross section
Occurring voltage load

X3, mains connection HCS01.1E-W0054-x-03

Identifica‐
tion
L1
L2
L3
Unit
mm
2
AWG
mm
Nm
Tab. 6-3:
Function, pin assignment, properties
Bosch Rexroth AG
Function
Connection to mains power supply (L1)
Connection to mains power supply (L2)
Connection to mains power supply (L3)
min.
0.75
18
14
1.5
See technical data of device used (I
See technical data of device used (U
131/341
Mounting and installation
max.
10.0
8
1.7
and A
)
LN
LN
or U
)
LN
LN_nom