Required Drive Firmware; Required Controller Configuration - Bosch Rexroth IndraDrive Series Applications Manual

Integrated safety technology 'safe torque off' (as of mpx-16)
Table of Contents
84/149
Bosch Rexroth AG
Commissioning the safety technology
8.2.2

Required drive firmware

8.2.3

Required controller configuration

General information
Optional safety technology module "L3"
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Rexroth IndraDrive Integrated Safety Technology "Safe Torque Off" (as of MPx-16)
WARNING
For selection and the 24 V supply of devices with integrated safety
technology, use a 24 V power supply unit with protection by SELV
accordance with IEC 60950-1 or PELV
The safety technology functions provided by the "L options" are functionalities
only scalable by means of the hardware and do not require any additional
enabling of functional firmware packages.
The integrated safety functions can be used as of the following firmware
versions:
"Safe Torque Off" (L3):
IndraDrive Cs (HCS01.1): As of MPx-17V06
IndraDrive Mi (KSM02.x): As of MPB-17V08
IndraDrive Mi (KMS02.x): As of MPB-17V10
IndraDrive C (Cxx02.x control sections): As of MPx-18V06
IndraDrive M (Cxx02.x control sections): As of MPx-18V06
IndraDrive ML (Cxx02.5 control sections): As of MPx-19V02
"Safe Torque Off" and "Safe Brake Control" (L4) [IndraDrive Cs
(HCS01.1) only]: As of MPx-16V14
See also Functional Description of firmware "Firmware types"
To use the integrated safety technology of Rexroth IndraDrive controllers, the
drive controller has to be configured/equipped with the corresponding
optional safety technology module.
Using the "Safe Torque Off" function requires the optional safety technology
module "L3". The optional module can be ordered for the following
controllers:
IndraDrive Cs Basic (HCS01.1E-W00**-A0*-B)
IndraDrive Cs Economy (HCS01.1E-W00**-A0*-E)
IndraDrive Cs Advanced (HCS01.1E-W00**-A0*-A)
Motor-integrated servo drive KSM02
Near motor servo drive KSM02
Servo drives of the IndraDrive Mi type, which have been equipped
with the optional safety module "L3", may only be operated at the
drive connection box of the "KCU02.2" or "KCU02.3" type.
IndraDrive C (HCS02.1E-W00xx-A-03-xNNN and
Safety Extra Low Voltage
1)
Protective Extra Low Voltage
2)
DOK-INDRV*-SI3-**VRS**-AP06-EN-P
In the case of error, injury and property
damage due to inadmissibly high voltage!
2)
in accordance with IEC 60204-1.
1)
in
Table of Contents
loading

Table of Contents