Sto And Sbc Functions ("L4" Only) When Selected By Means Of Active Safety Units - Bosch Rexroth IndraDrive Series Applications Manual

Integrated safety technology 'safe torque off' (as of mpx-16)
Table of Contents
DOK-INDRV*-SI3-**VRS**-AP06-EN-P
Rexroth IndraDrive Integrated Safety Technology "Safe Torque Off" (as of MPx-16)
7.1.2
STO and SBC functions ("L4" only) when selected by means of active
safety units
Dual-channel wiring
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Plus-plus-switching safety unit
When the safety function is selected by means of a plus-plus-switching safety
unit, the following errors must be detected by the OSSD outputs:
Short circuit of the selection signals with 24 V
Short circuit between the two selection signals
Fig. 7-3:
STO function and SBC function (only IndraDrive Cs with "L4") with ac‐
tive safety unit (plus-plus-switching outputs)
Plus-minus-switching safety unit
When the safety function is selected by means of a plus-minus-switching
safety unit, the following errors must be detected by the OSSD outputs:
Short circuit of the plus-switching selection signal against 24 V
Short circuit of the minus-switching selection signal against 0 V
Bosch Rexroth AG
61/149
Examples of application
Table of Contents
loading

Table of Contents