Bosch Rexroth IndraDrive Series Applications Manual page 54

Integrated safety technology 'safe torque off' (as of mpx-16)
Table of Contents
DOK-INDRV*-SI3-**VRS**-AP06-EN-P
Rexroth IndraDrive Integrated Safety Technology "Safe Torque Off" (as of MPx-16)
Pertinent parameters
Pertinent diagnostic messages
Safety function
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
In the case of IndraDrive Cs, IndraDrive C, IndraDrive M and
IndraDrive ML, the selection can take place via one channel,
alternatively by means of
a passive safety unit with an isolated conventional (non-solid-state)
normally closed contact (designed in compliance with SIL3), e.g.,
safety switching device for emergency stop, safety door monitor,
etc.
In addition, the fault exclusion (short-circuit with other signals /
potentials) in the wiring (considering IEC 61800-5-2: 2007, table D.
1 or ISO 13849-2: 2008, table D.4) is required, or
by means of an active safety unit with plus-switching OSSD output
(e.g., safety control units, laser scanners, etc.).
In addition, the fault exclusion (short-circuit with other signals /
potentials) in the wiring (considering IEC 61800-5-2: 2007, table D.
1 or ISO 13849-2: 2008, table D.4) is required.
The dynamization of the safety function selection takes place
alternatively by means of
the OSSD dynamization of the active safety unit or
the dynamization outputs at the X49 terminal connector of the
optional safety technology module "L3" or "L4" in the case of
control by passive safety units.
It is possible to set up a zone by connecting up to 25 drives in parallel.
Online dynamization of the outputs and interrupting circuits
Short reaction time [18 ms (108 ms with IndraDrive ML)]
The state of safety function "Safe Torque Off" is displayed via parameter
"P-0-0106, Operating status STO/SBC".
The following parameters are used in conjunction with the safety function
"Safe Torque Off":
P-0-0101, Configuration STO/SBC
P-0-0106, Operating status STO/SBC
The following diagnostic messages can be generated in conjunction with the
safety function "Safe Torque Off":
A0011 STO/SBC active
E8027 STO/SBC while drive enabled
F3134 Dynamization time interval incorrect
F8027 STO/SBC while drive enabled
F8300 Dynamization pulse width incorrect
F8301 Error when checking selection signals
F8302 Error when checking switch-off channels STO/SBC
F8303 System error STO/SBC
With the safety function "Safe Torque Off" activated, the display of the drive
controller's control panel shows "STO".
The optional safety technology modules "L3"/"L4" feature two 24 V inputs for
dual-channel selection and two dynamization outputs for operation at passive
safety units.
Bosch Rexroth AG
51/149
Integrated safety functions
Table of Contents
loading

Table of Contents