Comparison with conventional safety technology
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
The operational safety of machines and installations depends largely upon
the extent of dangerous movements generated by the machine.
In normal operation (also called productive operation or automatic operation),
protective equipment prevents humans from accessing danger zones and
keeps parts / materials from being thrown outward.
In the special mode (also called manual mode or setting-up mode), it is often
necessary for persons to access danger zones when the entire installation
has not been de-energized. In such situations machine operators must be
protected by mechanisms internal to the drive and the control unit.
The integrated Rexroth safety technology provides the user the requirements,
on the control unit and drive side, for realizing functions of personal and
machine protection with a minimum of planning and installation work
required. Compared to conventional safety technology, the integrated safety
technology considerably increases the functionality and availability of your
machine. Integrated safety technology is characterized by the following
features:
Complies with valid standards
Increased system performance
Reduced system costs
Easy understanding of complex subjects
Improved diagnostics
Simplified certification
Easy commissioning
Independent of control units
A drive and control system with integrated safety technology differs from
systems with conventional safety technology by the fact that the safety
functions are directly integrated in the intelligent drives in the form hardware
and software. This increases the functionality in all operation modes with a
maximum of safety (short reaction times).
The power contactor between controller and motor required for the
conventional safety technology is not included in drive and control systems
with the integrated safety technology "Safe Torque Off".
The integrated safety technology is not intended to replace
conventional safety technology, such as EMERGENCY STOP
monitoring devices and safety door monitors.
Using the integrated safety technology increases the available personnel and
machine safety, because the total reaction time of the system in the case of
an error event, for example, is considerably reduced with regard to
comparable systems with conventional safety technology. The safety signals
are transmitted with conventional wiring.