Siemens SINAMICS S120 Function Manual page 940

Hide thumbs Also See for SINAMICS S120:
Table of Contents
Basic information about the drive system
12.14 Write and know-how protection
Specifying the general memory data
The "General" tab is displayed automatically when the dialog is called. The "Save normally"
option is activated by default.
1. If you want to save the data in compressed form, click the "Save compressed (.zip
2. If you want to store additional data, such as program sources, on the target device,
3. Then enter the path for the storage directory in the appropriate input field, or click
Configuring know-how protection
Make the settings for the know-how protection on the "Drive unit know-how protection" tab.
1. Click the "Drive unit know-how protection" tab.
938
archive)" option button.
The "Store additional data on the target device" option is deactivated in the default
setting.
activate this option.
– Optionally you can also activate "Including DCC chart data". Graphical chart data can
then also be stored.
"Browse" and select the directory in your file system.
Figure 12-33 Load to file system know-how protection