Supplementary conditions for the use of third-party motors
● The procedure is very suitable for motors with magnets within the rotor core (IPMSM -
● The ratio of stator quadrature reactance (Lsq): Stator direct-axis reactance (Lsd) must be
● The asymmetrical reactance ratio (Lsq:Lsd) is maintained in the motor up to a certain
The following parameter input is prerequisite for optimal performance:
● Saturation characteristic: p0362 to p0369
● Load characteristic: p0398, p0399
Commissioning sequence for closed-loop controlled operation to zero speed:
● Run through the commissioning with motor identification at standstill.
● Enter the parameters for the saturation characteristic and the load characteristic.
● Activate closed-loop controlled operation down to zero speed via parameter p1750.5 = 1.
The following advantages are obtained by maintaining closed-loop controlled operation:
● No torque irregularities as a result of changeover operations in the closed-loop control
● Closed-loop speed and torque control without encoder (sensorless) up to and including 0
● Higher dynamic performance when compared to open-loop controlled operation
● Encoderless operation of drive line-ups (e.g. in the paper industry, master-slave
● Active (including hanging/suspended) loads down to zero frequency.
Note
Motor reactor, sine-wave filter, dv/dt filter
The process cannot be used with the present motor reactors, sine-wave filters and dv/dt
filters.
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Interior Permanent Magnet Synchronous Motors).
> 1.5.
current; this determines the possible operating limits of the method. If the procedure
should be operable up to the rated motor torque, then the reactance ratio must be
retained up to the rated motor current.