Preconditions for PN Gate

Hardware
● SINAMICS CU320-2 PN with firmware version as of 4.5
● Communication Board Ethernet 20 (CBE20)
● Short Ethernet cable to connect CBE20 and CU320-2 PN (X 132)
● Control hardware with Ethernet (100 Mbit/s or higher),
Note
The Gate PC must guarantee the short latency times required for operating the PN Gate.
Influencing variables are the CPU performance, mainboard hardware (Ethernet chipset and
its connection), and the BIOS and software components involved (operating system
components such as memory mapping, Ethernet driver, interrupt link, configuration).
Software
● SIMATIC STEP 7 firmware version as of 5.5 SP2
● STARTER firmware version 4.3, or
● SIMOTION SCOUT firmware version a of 4.3
PROFINET version
● SINAMICS PN Gate V2 is compatible with PROFINET V2.2
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Recommendation: Ethernet cable with the order number: 6SL3060-4AB00-0AA0
for example, the SIMATIC Box IPC 427C.