Terminal Modules - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents
PTC
● p4601[0...n] to p4603[0...n] = 10/11/12 sets the temperature sensor type PTC, the
● r4620[0...3] = -200 °C.
Bimetallic NC contact
● p4601[0...n] to p4603[0...n] = 30/31/32 sets the temperature sensor type bimetal NC
● r4620[0...3] = -200 °C.
8.5.4

Terminal Modules

Terminal Modules provided the drive system with additional analog and digital data inputs
and outputs. They are intended for use in control cabinets. The Terminal Modules are
connected via DRIVE-CLiQ with the drive system. Terminal Modules TM31, TM120 and
TM150 provide inputs for temperature sensors.
● The TM31 can evaluate one temperature sensor.
● The TM120 can evaluate up to 4 temperature sensors. The sensor inputs are electrically
● The TM150 can evaluate up to 12 sensors. The sensors can be split up into a maximum
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
evaluation type and activates the evaluation.
– p4601[0...n] = 10 PTC fault
– p4601[0...n] = 11 PTC alarm
– p4601[0...n] = 12 PTC alarm and timer
contact, the evaluation type and activates the evaluation.
– p4601[0...n] = 30 bimetal NC contact fault
– p4601[0...n] = 31 bimetal NC contact alarm
– p4601[0...n] = 32 bimetal NC contact alarm and timer
isolated.
of 3 groups. Each sensor can be freely assigned to one of the group.
Monitoring and protective functions
8.5 Thermal motor protection
543

Hide quick links:

Table of Contents
loading

Table of Contents