Converter operation despite pending messages
With activated safety functions, there are a number of system messages that still permit the
drive to be traversed. In these cases, you must ensure that the causes of the messages are
corrected immediately. These messages include, among others, the following:
• A01774 SI Motion CU: Test stop required
• A13000 License not sufficient.
• A01669 (F, N) SI Motion: Unsuitable combination of motor and power unit.
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
WARNING
A01697 SI Motion: Motion monitoring test required
The drive is being operated outside the valid probability of error (PFH). Perform the
required test stop.
Purchase the license required for the operation of the Extended Functions.
The motor / power unit combination can result in decreased robustness (incorrect
detection of errors) in the system when operating with SI Motion.