Function diagrams (see SINAMICS S120/S150 List Manual)
• 9794
• 9795
Overview of important parameters (see SINAMICS S120/S150 List Manual)
• r0046.29
• r0108.28
• p0192.06
• r0204.06
• p0260
• p0261
• p0262
• p0263
• p0264
• r0265.0...3
• p0266[0...7] BI: Cooling unit feedback signals signal source
• r0267.0...7
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Auxiliaries - Cooling unit, control and feedback signals (r0108.28 = 1)
Auxiliaries - Cooling unit, sequence control (r0108.28 = 1)
Missing enables; cooling unit ready missing
Drive object function module; cooling unit
Power unit firmware properties; water cooling
Power unit hardware properties; liquid cooling with cooling unit
(chassis power unit)
Cooling unit startup time 1
Cooling unit startup time 2
Cooling unit fault conductivity delay time
Cooling unit fault liquid flow delay time
Cooling unit delay time
BO: Cooling unit control word
BO: Cooling unit status word
Function modules
7.5 Cooling unit