Siemens SINAMICS S120 Function Manual page 369

Hide thumbs Also See for SINAMICS S120:
Table of Contents
Updating the firmware from the memory card to the latest version
1. Replacing the memory card.
2. Go online and download the project to the target device, then execute the "Copy RAM to
3. The firmware for the DRIVE-CLiQ components is automatically updated.
4. Wait until the Control Unit has completed the transfer of the new firmware. This is
5. Carry out a POWER ON for the drive unit (Control Unit and all DRIVE-CLiQ components).
Converting an existing project to new firmware
1. Is the project available in the STARTER commissioning tool?
2. Open the project using STARTER:
3. Converting the project to the current firmware version:
4. Transfer the project into the new hardware
5. Carry out a POWER ON for the drive unit (Control Unit and all DRIVE-CLiQ components).
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
– Disconnect the Control Unit from the power supply
– Remove the memory card containing the old firmware version
– Insert the memory card containing the new firmware version
– Power-up the Control Unit again
ROM..." command.
signaled at the diagnostic RDY LED.
After the complete power up, the new firmware version is active in the DRIVE-CLiQ
components and subsequently displayed in the version overview.
– If it is, then connect with the target system (go online)
– Continue with 3
– Connect to the target system (online mode)
– Load the project from the target system into the PG/PC
– Disconnect from the target device (offline mode)
– In the project navigator, right-click "Drive unit" > "Target device" > "Update device
version / device type"
– Select the required firmware version, e.g. version "SINAMICS S120 firmware version
4.x" > "Change version"
– Connect the new hardware with the PG/PC
– Connect to the target system (online mode)
– Load to the target device
After the complete power up, the project is active in the new firmware version in the
DRIVE-CLiQ components.
6.24 Upgrade the firmware and project