Kenwood NEXEDGE NX-200 Function Reference page 149

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents
8 NXDN CONVENTIONAL SYSTEM
8.1 Initiating Voice Communications (Basic Transmission and Reception)
TOT Rekey Time
TOT Rekey Time is the amount of time from when the transceiver stops the transmission by the Time-out Timer until
transmission becomes possible again.
Example: Time-out Timer: 30 s, TOT Rekey Time: 20 s
Note
• If "Off" is configured for TOT Rekey Time, the transceiver will immediately be ready to transmit.
• The timer will be reset if the zone or channel is changed while the TOT Rekey Time is counting down.
TOT Reset Time
TOT Reset Time is the time required to initialize and reset the elapsed time for Time-out Timer.
Example 1: Time-out Timer: 30 s, TOT Reset Time: 10 s
The transceiver considers a retransmission within this configured length of time as a continuous transmission. In the
following example, the counting of Time-out Timer continues because the transmission was started by a user pressing the
PTT switch while the TOT Reset Time was counting down.
Example 2: Time-out Timer: 30 s, TOT Reset Time: 10 s
Note
• If "Off" is configured for TOT Reset Time, the Time-out Timer will be reset immediately after the transceiver finishes transmitting.
• The timer will be reset if the zone or channel is changed while the TOT Reset Time is counting down.
Configuration using KPG-111D/ DN
Configuring the Time-out Timer (
Configuring the TOT Pre-alert (
Configuring the TOT Rekey Time (
Configuring the TOT Reset Time (
FUNC (K)/Ver 4.00
PTT
Press
TOT
Count Start
TOT Rekey Time
Count Start
0 s
Time
Figure 8-3 TOT Rekey Time
PTT
Press
Release
TOT
Count Start
TOT Reset Time
TOT Reset Time
Count Start
Time
0 s
10 s
Figure 8-4 TOT Reset Time 1
PTT
Press
TOT
Count Start
TOT Reset Time
Count Start
Time
0 s
10 s
Figure 8-5 TOT Reset Time 2
FPRG 8.2.8 Time-out Timer (TOT))
See
FPRG 8.2.9 TOT Pre-alert)
See
FPRG 8.2.10 TOT Rekey Time)
See
FPRG 8.2.11 TOT Reset Time)
See
Release
Press
Expire TOT
Count Start
TOT Rekey Time
Expire
30 s
50 s
Press
TOT Reset
Count Start
Expire
20 s
25 s
30 s
55 s
Release
Press
Expire TOT
TOT Reset Time
Expire
20 s
30 s
Expire TOT
CONTENTS