IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
6.2.7
X53, Control Voltage Output
View
Screw terminal (connector at hybrid
cable)
Tightening torque
Connection cable stranded wire
Connection cable
Output data
Short circuit protection
Overload protection
Control Voltage Monitoring
Notes on Operation
WARNING
Do not remove connectors when the component has been powered. Do not
plug in connectors when the component has been powered.
Wait at least 30 minutes after switching off the supply voltages to allow
discharging.
Connection
Signal name
1 (WH*)
GND
2 (GN*)
42 V
Unit
Min.
Nm
1,5
mm
2
AWG
–
–
*
Conductor color of the ready-made cable RKH
Tab. 6-10:
Function, Pin Assignment, Properties
The control voltage is constantly monitored. If the allowed voltage range is
left, the control voltage for the connected KSM02/KMS02 devices is switched
off and LED H53 emits red light. Thereafter, the motors are coasting down
because a return movement is no longer possible.
Do not remove connectors when the component has been powered. Do not
plug in connectors when the component has been powered.
High electrical voltage! Danger to life by
electric shock!
Function
●
Output of DC-DC converter (24V – 42V) in
KCU02
(GND is not connected to 0V of the 24V
supply)
●
Supplies KSM02/KMS02 with control
voltage
Max.
1,7
Connection via hybrid cable RKH
U
, P
(see technical data of KCU02)
out
out
Present
Present
R911335703_Edition 04 Bosch Rexroth AG
151/407
Connection points